這真不是您需要的服務(wù)?
Cord Sets and Power-supply Cords
Guide Information for Electrical Equipment for Use in Ordinary LOCAIIONs
GENERAL
This category covers cord sets and power-supply cords for use as supply connections for portable appliances and the like.
This category also covers bulk certified power-supply cords that are repackaged from their original packaging.
Cord sets and power-supply cords are not intended to be used as a substitute for the fixed wiring of a structure and, hence, are not intended to be fastened in place. Cord sets and shore-power cable sets are rated in volts, amps and watts.
Cord sets and power-supply cords are commonly furnished in hanked or coiled bbbb. If used in this condition, excessive heating may occur. Therefore, when placed into service, all wrappings should be removed, and the flexible cord should be extended for its entire length.
Hospital-grade cord sets and power-supply cords are intended for use in hospitals and health care facilities in other than hazardous (classified) LOCAIIONs. Hospital-grade attachment plugs are of the NEMA 5-15P, 5-20P, 6-15P or 6-20P configuration, either of straight or right-angle type. Hospital-grade connectors are of the NEMA 5-15P, 5-20P, 6-15P or 6-20P, either of straight or right-angle type, IEC 60320-1, "Appliance Couplers for Household and Similar General Purposes - Part 1: General Requirements," or UL 60320-1, "Appliance Couplers for Household and Similar General Purposes - Part 1: General Requirements," or other non-NEMA approved configuration.
Cord sets and power-supply cords that employ ground-fault circuit interrupter protection are investigated to UL 943, "Ground-Fault Circuit-Interrupters," and covered under Ground-fault Circuit Interrupters (KCXS).
For information regarding the flexible cord types and their ratings, see Flexible Cord (ZJCZ).
Cord sets and power-supply cords that employ flexible cord bearing the "HF" marking and where combustible materials used in the construction of the plug-and-cord connector (when employed) of the cord set or power-supply cord (e.g., inner mold/enclosure, outer mold/enclosure) are determined to be halogen-free in accordance with UL 2885, "Outline of Investigation for Acid Gas, Acidity and Conductivity of Combusted Materials and Assessment of Halogens," may be surface marked on the plug and/or cord connector with the suffix "-HF" after the catalog number.
CORD SETS
A cord set consists of a length of flexible cord assembled (1) to an attachment plug or current tap as a line fitting and a cord connector as a load fitting, and with or without a through-cord switch, or (2) with a series-connected current tap and a pendant switch.
Cord sets are designated as one of the following types and are so identified by the Certification Mark:
Extension Cord Set — This is a cord set intended for general use indoors and assembled with general-use flexible cord and general purpose fittings. These cord sets may be less than six feet long. Cord sets shorter than six feet long are marked to indicate their length. Cord sets may also have integral restraint devices to prevent unintentional disconnection of the cord connector from a mating attachment plug of an appliance. Restraint devices that are separate from cord sets are covered under Cord Restraint Devices (ELDW).
Outdoor-use Extension Cord Set — This is a cord set assembled with outdoor-type flexible cord without a switch, and which is intended for use outdoor to supply portable electric equipment. It is (1) marked "Suitable For Use With Outdoor Appliances — Store Indoors While Not In Use," (2) suitable for supplying portable outdoor appliances within their marked voltage, amp and wattage rating, (3) intended for use outdoors only while the equipment supplied is in use, and (4) intended to be stored indoors (i.e., where not exposed to sunlight and/or weather) while not in use. Such a cord set has been investigated to determine (1) that the materials in the flexible cord and in the line and load fittings, and (2) the adhesion between the cord jacket and the bodies of the line and load fittings are suitable for periodic use outdoors.
The connection between the attachment plug cap and the outlet device supplying the cord set, and between the supply cord of any connected appliance and the load end of the cord set, should not be subjected to moisture or dampness. Outdoor-use cord sets may also have integral restraint devices to prevent unintentional disconnection of the cord connector from a mating attachment plug of an appliance. Restraint devices that are separate from cord sets are covered under Cord Restraint Devices (ELDW).
Adapter Cord Set — This is an outdoor-use cord set, without a switch, consisting of an attachment plug, a length of extra-hard-usage outdoor-type flexible cord, and one or more load fittings providing:
1. a total of not more than three outlets configured together, or configured with one or more flexible cords, or
2. up to six single-outlet load fittings, provided that each load fitting is in line and spaced apart from the others.
Adapter cord sets are intended for use in areas such as construction sites to provide power to two or three outlets from a single outlet, or to convert from one outlet configuration to another. An adapter cord set with more than one single-outlet load fitting may have a joint in the flexible cord with the cord branching to two or three cords, each terminating in a single-outlet load fitting.
Cord Set for Recreational Vehicles — This is an outdoor-use cord set intended for use in supplying power to recreational vehicles.
Shore-power Cable Set — A shore-power cable set is an outdoor-use cord set that is used in supplying power to boats moored to a dock. They are intended to be stored aboard the boat where not exposed to sunlight and/or weather while not in use. The line and load fittings are of the locking type, rated not less than 20 A and are intended to be connected to suitable shore-power outlet and hull-power inlet devices, respectively. The connection of the attachment plug to a shore-based power outlet and the connection of the cord connector to a shore-power inlet, aboard a boat, provides a seal against water. Shore-power cable sets are also covered under Shore-power Cable Sets, Marine (UBWW).
Appliance Cord Set — A cord set consists of a length of flexible cord assembled with (1) an attachment plug or current tap as a line fitting at one end, and (2) a single outlet load fitting (appliance coupler) at the opposite end. It is intended for use and packaging with appliances. It may be one of the following types:
Cord Set Having an Appliance Plug — This is a cord set, not less than 2 ft (0.61 m) long, with an appliance plug as a load fitting.
Cord Set Having a Flatiron Plug — This is a cord set, not less than 6 ft (1.8 m) long, having a heater cord and a flatiron plug as a load fitting.
Cord Set for Appliances Rated Not Greater Than 50 W — This is a cord set for use with hand-held appliances rated 50 W or less and having a load fitting (appliance coupler) for use with electric shavers, electric scissors, electric combs, and the like.
Cord Set - Special Use — A special-use cord set is intended for restricted use and incorporates special design features (such as special cords and fittings) for a specific application. Each is provided with marking pertinent to its proper use, and/or limitations and electrical rating.
Cord Set - Hospital Grade — A cord set having a hospital-grade attachment plug and a hospital-grade connector of the IEC 60320-1 or UL 60320-1 or other non-NEMA-approved configuration.
Extension Cord Set - Hospital Grade — A cord set having a hospital-grade attachment plug and a hospital-grade cord connector of the same mating configuration.
POWER-SUPPLY CORDS
Power-supply cords are inherently nondetachable type, and may employ additional components such as an integral strain relief bushing or individual terminals.
Power-supply cords are designated as one of the following types:
Power-supply Cord — This is a power-supply cord consisting of a length of flexible cord assembled with an attachment plug or current tap as a line fitting but without a cord connector (appliance coupler) at the opposite end. It is intended for direct wiring connection to an appliance and may include a through-cord switch. It may have additional components such as an integral strain relief bushing or individual terminals. Power-supply cords may be one of the following:
Outdoor-use Power-supply Cord — This is a power-supply cord assembled with outdoor-type flexible cord. It is for use with portable outdoor appliances.
Power-supply Cord for Recreational Vehicles — This is an outdoor-use power-supply cord with the outer surface of the flexible cord marked "For Recreational Vehicle Use: ___ Amps."
Power-supply Cord for Mobile Homes — This is an outdoor-use power-supply cord with the outer surface of the flexible cord marked "For Mobile Home Use: ___ Amps."
Power-supply Cord - Special Use — A special-use power-supply cord is intended for restricted use and incorporates special design features (such as special cords and fittings) for a specific application. Each is provided with marking pertinent to its proper use, and/or limitations and electrical rating.
Power-supply Cord - Hospital Grade — A power-supply cord having a hospital-grade attachment plug.
PRODUCT IDENTITY
One of the following product identities appears on the product:
Adapter Cord Set
Cord Set
Cord Set - Special Use
Cord Set for Recreational Vehicles
Extension Cord Set
Hospital-grade Cord Set
Hospital-grade Extension Cord Set
Hospital-grade Power-supply Cord
Outdoor-use Extension Cord Set
Outdoor-use Power-supply Cord
Power-supply Cord
Power-supply Cord - Special Use
Power-supply Cord for Mobile Homes
Power-supply Cord for Recreational Vehicles
Replacement Detachable Power-supply Cord
Replacement Outdoor-use Power-supply Cord
Replacement Power-supply Cord
Shore-power Cable Set
The update from UL 817 (11th ed.) to UL 817 (12th ed.) included revisions to the definitions of various products. Below is a correlation of the definitions between the two editions.
Product Identity in UL 817 (11th ed.) | Product Identity in UL 817 (12th ed.) |
---|---|
Cord Set - Adapter | Adapter Cord Set |
Cord Set - General Use | General Use Extension Cord Set |
Cord Set - Outdoor Use | Outdoor Use Extension Cord Set |
Cord Set - Recreational Vehicle | Recreational Vehicle Cord Set |
Detachable Power Supply Cord - General Use | General Use Cord Set |
Detachable Power Supply Cord - Special Use | Special Use Cord Set |
Detachable Power Supply Cord for Appliances Rated 50 W or Less | Cord Sets for Appliances Rated 50 W or Less |
Detachable Power Supply Cord Having Appliance Plug | Cord Set Having Appliance Plug |
Detachable Power Supply Cord Having Flatiron Plug | Cord Set Having Flatiron Plug |
Nondetachable Power Supply Cord - General Use | General Use Power Supply Cord |
Nondetachable Power Supply Cord - Mobile Home | Mobile Home Power Supply Cord |
Nondetachable Power Supply Cord - Outdoor Use | Outdoor Use Power Supply Cord |
Nondetachable Power Supply Cord - Range and Dryer | Range and Dryer Power Supply Cord and Kit |
Nondetachable Power Supply Cord - Recreational Vehicle | Recreational Vehicle Power Supply Cord |
Nondetachable Power Supply Cord - Special Use | Special Use Power Supply Cord |
Shore Power Cable Set | Shore Power Cable Set |
— | Hospital Grade Cord Set |
— | Hospital Grade Extension Cord Set |
— | Hospital Grade Power Supply Cord |
RELATED PRODUCTS
Power-supply cords intended for use with waste disposers are investigated to UL 430, "Waste Disposers," and covered under Waste Disposers, Sink Mounted (ZDII). Only those power-supply cords that have been investigated to UL 430 are permitted to be marked "Garbage Disposal Cord," or the equivalent.
ADDITIONAL INFORMATION
For additional information, see Electrical Equipment for Use in Ordinary LOCAIIONs (AALZ).
REQUIREMENTS
The basic standard used to investigate products in this category is UL 817, "Cord Sets and Power-Supply Cords."
Molded-on IEC-configuration fittings are additionally investigated to the applicable requirements of UL 60320-1, "Appliance Couplers for Household and Similar General Purposes - Part 1: General Requirements."
UL MARK
The Certification Mark of UL on the product is the only bbbbbb provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number.
The Certification Mark for this category requires the use of a holographic label.
All Certification Marks are applied to each individual piece except for "Power-supply Cord," "Outdoor-use Power-supply Cord" and "Detachable Power-supply Cord." These products are bulk labeled (label applied to smallest container indicating number of pieces) and are not intended for field application.
Alternate UL Mark
The Listing Mark of UL on the product is the only bbbbbb provided by UL to identify products manufactured under its Listing and Follow-Up Service. The Listing Mark for these products includes the UL symbol (as illustrated in the Introduction of this Directory) together with the word "LISTED," a control number, and one of the following product names as appropriate::
Adaptor Cord Set
Cord Set
Cord Set - Special Use
Cord Set for Recreational Vehicle
Extension Cord Set
Outdoor Use Extension Cord Set
Outdoor Use Power Supply Cord
Power Supply Cord
Power Supply Cord - Special Use
Power Supply Cord for Mobile Home
Power Supply Cord for Recreational Vehicle
Replacement Cord Set
Replacement Outdoor Use Power Supply Cord
Replacement Power Supply Cord
Shore Power Cable Set
All Listing Marks are applied to each individual piece except for "Cord Set," "Outdoor Use Power Supply Cord" and "Power Supply Cord." These products are bulk labeled (label applied to smallest container indicating number of pieces) and are not intended for field application.
The Listing Mark for this category requires the use of a holographic label.
* * * * * * * * * * * * * * * * * * * * * * * * *
UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information.
插頭UL認(rèn)證標(biāo)準(zhǔn):
UL817 適用于電線(xiàn)組件和電源線(xiàn)插頭
插頭UL認(rèn)證_UL817認(rèn)證檢測(cè)項(xiàng)目:
導(dǎo)線(xiàn)連接可靠性測(cè)試、端子牢固性測(cè)試、絕緣皮牢固性測(cè)試、防拉力傳入測(cè)試、散絲與斷絲目檢、軟線(xiàn)連接器觸片下陷深度檢、測(cè)插孔深度測(cè)量、絕緣耐壓測(cè)試、極性與導(dǎo)通測(cè)試、絕緣電阻測(cè)試、突拉測(cè)試、外被保持測(cè)試、高溫吊端子測(cè)試、搖擺測(cè)試。
插頭UL認(rèn)證_UL817認(rèn)證辦理流程:
1、項(xiàng)目確定:確認(rèn)試驗(yàn)所依據(jù)的UL標(biāo)準(zhǔn)、認(rèn)證費(fèi)用與時(shí)間、樣品數(shù)量等
2、資料準(zhǔn)備:根據(jù)UL的要求,企業(yè)準(zhǔn)備好認(rèn)證所需的各項(xiàng)資料或文件;
3、送樣測(cè)試:企業(yè)將樣品寄送至廣東優(yōu)爾檢測(cè)實(shí)驗(yàn)室進(jìn)行產(chǎn)品測(cè)試;
4、簽發(fā)報(bào)告:產(chǎn)品檢測(cè)結(jié)果符合UL標(biāo)準(zhǔn)要求,正式簽發(fā)檢測(cè)報(bào)告;
5、工廠(chǎng)審核:UL將對(duì)生產(chǎn)工廠(chǎng)進(jìn)行工廠(chǎng)檢查,以確保符合標(biāo)準(zhǔn)要求;
6、標(biāo)志使用:審核符合要求后,申請(qǐng)人正式獲得授權(quán)使用UL標(biāo)志。
優(yōu)爾檢測(cè)電線(xiàn)電纜全球燃燒測(cè)試中心
優(yōu)爾檢測(cè)(廣東)有限公司-優(yōu)爾檢測(cè)華南檢測(cè)中心,地址:惠州市博羅縣石灣鎮(zhèn)滘源路滘嚇馮屋草州A棟和C棟,實(shí)驗(yàn)室和辦公用地:4500平米,總投資3000多萬(wàn),擁有儀器設(shè)備500余套,在物理,化學(xué),可靠性,環(huán)保(RoHS, Reach,CP65等),燃燒等方面擁有豐富的檢測(cè)經(jīng)驗(yàn)和技術(shù)實(shí)力.依據(jù)全球各國(guó)標(biāo)準(zhǔn)對(duì)電線(xiàn)電纜及橡塑化工材料在阻燃、耐火、低煙、無(wú)鹵、環(huán)保、可靠性、電氣特性方面的要求而建立。在全球各大認(rèn)證機(jī)構(gòu)(UL、VDE、CCC、IMQ、 TUV-RHEINLAND、TUV-SUD、CSA、BASEC、KEMA、PSE、KC、TLC、ETC、GRL、ANATEL、EAC)和廣大客戶(hù)的認(rèn)可和支持下,我們希望能成為燃燒測(cè)試基地,服務(wù)于來(lái)自全球的終端客戶(hù)、電商平臺(tái)、布線(xiàn)廠(chǎng)商、線(xiàn)纜及材料企業(yè)!
優(yōu)爾檢測(cè)電線(xiàn)電纜全球燃燒測(cè)試中心,僅燃燒測(cè)試實(shí)驗(yàn)室用地就達(dá)到1100多平方,投資約1500多萬(wàn),
電線(xiàn)電纜燃燒測(cè)試中心檢測(cè)范圍:
(1)網(wǎng)線(xiàn)/光纜/功率線(xiàn)/火災(zāi)報(bào)線(xiàn)/天線(xiàn):美國(guó)UL/加拿大CSA標(biāo)準(zhǔn): CM/CMR/CMP/FT4/FT6級(jí)大型燃燒;
(2)歐洲建筑法規(guī)強(qiáng)制指令CPR EN50399標(biāo)準(zhǔn)成束熱釋放量燃燒,B,C,D,E等級(jí)全項(xiàng)測(cè)試;
(3)國(guó)標(biāo)GB18380線(xiàn)纜成束燃燒 A, B, C,D級(jí)成束燃燒;
(4)英國(guó)耐火線(xiàn)纜BS6387和BS8491,GB/T 19666(N,NJ,NS);
(5)美國(guó)VW-1/IEC60332-1-2/EN60332-1-2單根垂直燃燒;
(6)橡塑材料UL94/國(guó)標(biāo)GB/T 8815阻燃測(cè)試;
( 7)氧指數(shù)、鹵酸氣體、灼熱絲、漏電起痕、PH值等測(cè)試
詳詢(xún)Sunny 陶靜13913142465